Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 23
Filter
Add more filters










Publication year range
1.
J Biomech ; 169: 112131, 2024 May 04.
Article in English | MEDLINE | ID: mdl-38739987

ABSTRACT

Cartilage endplates (CEPs) act as protective mechanical barriers for intervertebral discs (IVDs), yet their heterogeneous structure-function relationships are poorly understood. This study addressed this gap by characterizing and correlating the regional biphasic mechanical properties and biochemical composition of human lumbar CEPs. Samples from central, lateral, anterior, and posterior portions of the disc (n = 8/region) were mechanically tested under confined compression to quantify swelling pressure, equilibrium aggregate modulus, and hydraulic permeability. These properties were correlated with CEP porosity and glycosaminoglycan (s-GAG) content, which were obtained by biochemical assays of the same specimens. Both swelling pressure (142.79 ± 85.89 kPa) and aggregate modulus (1864.10 ± 1240.99 kPa) were found to be regionally dependent (p = 0.0001 and p = 0.0067, respectively) in the CEP and trended lowest in the central location. No significant regional dependence was observed for CEP permeability (1.35 ± 0.97 * 10-16 m4/Ns). Porosity measurements correlated significantly with swelling pressure (r = -0.40, p = 0.0227), aggregate modulus (r = -0.49, p = 0.0046), and permeability (r = 0.36, p = 0.0421), and appeared to be the primary indicator of CEP biphasic mechanical properties. Second harmonic generation microscopy also revealed regional patterns of collagen fiber anchoring, with fibers inserting the CEP perpendicularly in the central region and at off-axial directions in peripheral regions. These results suggest that CEP tissue has regionally dependent mechanical properties which are likely due to the regional variation in porosity and matrix structure. This work advances our understanding of healthy baseline endplate biomechanics and lays a groundwork for further understanding the role of CEPs in IVD degeneration.

2.
Adv Healthc Mater ; : e2303706, 2024 Mar 24.
Article in English | MEDLINE | ID: mdl-38523366

ABSTRACT

The shortage of suitable donor meniscus grafts from the knee and temporomandibular joint (TMJ) impedes treatments for millions of patients. Vitrification offers a promising solution by transitioning these tissues into a vitreous state at cryogenic temperatures, protecting them from ice crystal damage using high concentrations of cryoprotectant agents (CPAs). However, vitrification's success is hindered for larger tissues (>3 mL) due to challenges in CPA penetration. Dense avascular meniscus tissues require extended CPA exposure for adequate penetration; however, prolonged exposure becomes cytotoxic. Balancing penetration and reducing cell toxicity is required. To overcome this hurdle, a simulation-based optimization approach is developed by combining computational modeling with microcomputed tomography (µCT) imaging to predict 3D CPA distributions within tissues over time accurately. This approach minimizes CPA exposure time, resulting in 85% viability in 4-mL meniscal specimens, 70% in 10-mL whole knee menisci, and 85% in 15-mL whole TMJ menisci (i.e., TMJ disc) post-vitrification, outperforming slow-freezing methods (20%-40%), in a pig model. The extracellular matrix (ECM) structure and biomechanical strength of vitreous tissues remain largely intact. Vitreous meniscus grafts demonstrate clinical-level viability (≥70%), closely resembling the material properties of native tissues, with long-term availability for transplantation. The enhanced vitrification technology opens new possibilities for other avascular grafts.

3.
J Appl Mech ; 91(2)2024 Feb.
Article in English | MEDLINE | ID: mdl-38449742

ABSTRACT

Natural protective materials offer unparalleled solutions for impact-resistant material designs that are simultaneously lightweight, strong, and tough. Particularly, the Bouligand structure found in the dactyl club of mantis shrimp and the staggered structure in nacre achieve excellent mechanical strength, toughness, and impact resistance. Previous studies have shown that hybrid designs by combining different bioinspired microstructures can lead to enhanced mechanical strength and energy dissipation. Nevertheless, it remains unknown whether combining Bouligand and staggered structures in nanofibrillar cellulose (NFC) films, forming a discontinuous fibrous Bouligand (DFB) architecture, can achieve enhanced impact resistance against projectile penetration. Additionally, the failure mechanisms under such dynamic loading conditions have been minimally understood. In our study, we systematically investigate the dynamic failure mechanisms and quantify the impact resistance of NFC thin films with DFB architecture by leveraging previously developed coarse-grained models and ballistic impact molecular dynamics simulations. We find that when nanofibrils achieve a critical length and form DFB architecture, the impact resistance of NFC films outperforms the counterpart films with continuous fibrils by comparing their specific ballistic limit velocities and penetration energies. We also find that the underlying mechanisms contributing to this improvement include enhanced fibril sliding, intralayer and interlayer crack bridging, and crack twisting in the thickness direction enabled by the DFB architecture. Our results show that by combining Bouligand and staggered structures in NFC films, their potential for protective applications can be further improved. Our findings can provide practical guidelines for the design of protective films made of nanofibrils.

4.
J Orthop Res ; 2024 Mar 09.
Article in English | MEDLINE | ID: mdl-38460961

ABSTRACT

Established risk factors for osteoarthritis (OA) include obesity, joint injury, age, race, and genetics. However, the relationship between cigarette smoking and OA has yet to be established. In the present study, we have employed the use of cigarette smoke extract (CSE), the water-soluble vapor phase of cigarette smoke, with porcine cartilage explants to investigate the effects of cigarette smoking on cartilage catabolism at the tissue level. Articular cartilage explants were first exposed to 2.5%, 5%, and 10% CSE to assess its effects on cartilage homeostasis. Following, the effects of CSE on OA-like inflammation was observed by culturing explants with a combined treatment of IL-1ß and TNF-α and 10% CSE (CSE + OA). Cartilage explants were assessed for changes in viability, biochemical composition, extracellular matrix (ECM) integrity, and equilibrium mechanical properties (aggregate modulus and hydraulic permeability). CSE alone leads to both a time- and dose-dependent decrease in chondrocyte viability but does not significantly affect sGAG content, percent sGAG loss, or the ECM integrity of cartilage explants. When IL-1ß and TNF-α were combined with 10% CSE, this led to a synergistic effect with more significant losses in viability, significantly more sGAG loss, and significantly higher production of ROS than OA-like inflammation only. Cartilage explant equilibrium mechanical properties were unaffected. Within the timeframe of this study, CSE alone does not cause OA but when combined with OA-like inflammation leads to worsened articular cartilage degeneration as measured by chondrocyte viability, sGAG loss, proteoglycan staining, and ROS production.

5.
J Biomed Mater Res A ; 112(3): 421-435, 2024 03.
Article in English | MEDLINE | ID: mdl-37964720

ABSTRACT

Focal chondral defects (FCDs) significantly impede quality of life for patients and impose severe economic costs on society. One of the most promising treatment options-autologous matrix-induced chondrogenesis (AMIC)-could benefit from a scaffold that contains both of the primary cartilage matrix components-sulfated glycosaminoglycans (sGAGs) and collagen type II. Here, 17 different protocols were evaluated to determine the most optimum strategy for decellularizing (decelling) the bovine nucleus pulposus (bNP) to yield a natural biomaterial with a cartilaginous constituency. The resulting scaffold was then characterized with respect to its biochemistry, biomechanics and cytocompatibility. Results indicated that the optimal decell protocol involved pre-crosslinking the tissue prior to undergoing decell with trypsin and Triton X-100. The residual DNA content of the scaffold was found to be 32.64 ± 9.26 ng/mg dry wt. of tissue with sGAG and hydroxyproline (HYP) contents of 72.53 ± 16.43. and 78.38 ± 8.46 µg/mg dry wt. respectively. The dynamic viscoelastic properties were found to be preserved (complex modulus: 17.92-16.62 kPa across a range of frequencies) while the equilibrium properties were found to have significantly decreased (aggregate modulus: 11.51 ± 9.19 kPa) compared to the non-decelled fresh bNP tissue. Furthermore, the construct was also found to be cytocompatible with bone marrow stem cells (BMSCs). While it was not permissive of cellular infiltration, the BMSCs were still found to have lined the laser drilled channels in the scaffold. Taken together, the biomaterial developed herein could be a valuable addition to the AMIC family of scaffolds or serve as an off-the-shelf standalone option for cartilage repair.


Subject(s)
Cartilage, Articular , Nucleus Pulposus , Humans , Animals , Cattle , Tissue Scaffolds/chemistry , Quality of Life , Cartilage , Biocompatible Materials , Chondrogenesis , Tissue Engineering/methods
6.
J Biomech Eng ; 145(7)2023 07 01.
Article in English | MEDLINE | ID: mdl-36752723

ABSTRACT

The cartilage endplates (CEPs) on the superior and inferior surfaces of the intervertebral disk (IVD), are the primary nutrient transport pathways between the disk and the vertebral body. Passive diffusion is responsible for transporting small nutrient and metabolite molecules through the avascular CEPs. The baseline solute diffusivities in healthy CEPs have been previously studied, however alterations in CEP diffusion associated with IVD degeneration remain unclear. This study aimed to quantitatively compare the solute diffusion in healthy and degenerated human CEPs using a fluorescence recovery after photobleaching (FRAP) approach. Seven healthy CEPs and 22 degenerated CEPs were collected from five fresh-frozen human cadaveric spines and 17 patients undergoing spine fusion surgery, respectively. The sodium fluorescein diffusivities in CEP radial and vertical directions were measured using the FRAP method. The CEP calcification level was evaluated by measuring the average X-ray attenuation. No difference was found in solute diffusivities between radial and axial directions in healthy and degenerated CEPs. Compared to healthy CEPs, the average solute diffusivity was 44% lower in degenerated CEPs (Healthy: 29.07 µm2/s (CI: 23.96-33.62 µm2/s); degenerated: 16.32 µm2/s (CI: 13.84-18.84 µm2/s), p < 0.001). The average solute diffusivity had an inverse relationship with the degree of CEP calcification as determined by the normalized X-ray attenuation values (ß = -22.19, R2 = 0.633; p < 0.001). This study suggests that solute diffusion through the disk and vertebral body interface is significantly hindered by CEP calcification, providing clues to help further understand the mechanism of IVD degeneration.


Subject(s)
Calcinosis , Intervertebral Disc Degeneration , Intervertebral Disc , Humans , Cartilage/metabolism , Intervertebral Disc/metabolism , Intervertebral Disc Degeneration/metabolism , Biological Transport , Diffusion
7.
Commun Biol ; 6(1): 220, 2023 02 24.
Article in English | MEDLINE | ID: mdl-36828843

ABSTRACT

Successful organ or tissue long-term preservation would revolutionize biomedicine. Cartilage cryopreservation enables prolonged shelf life of articular cartilage, posing the prospect to broaden the implementation of promising osteochondral allograft (OCA) transplantation for cartilage repair. However, cryopreserved large sized cartilage cannot be successfully warmed with the conventional convection warming approach due to its limited warming rate, blocking its clinical potential. Here, we develope a nanowarming and ice-free cryopreservation method for large sized, intact articular cartilage preservation. Our method achieves a heating rate of 76.8 °C min-1, over one order of magnitude higher than convection warming (4.8 °C min-1). Using systematic cell and tissue level tests, we demonstrate the superior performance of our method in preserving large cartilage. A depth-dependent preservation manner is also observed and recapitulated through magnetic resonance imaging and computational modeling. Finally, we show that the delivery of nanoparticles to the OCA bone side could be a feasible direction for further optimization of our method. This study pioneers the application of nanowarming and ice-free cryopreservation for large articular cartilage and provides valuable insights for future technique development, paving the way for clinical applications of cryopreserved cartilage.


Subject(s)
Cartilage, Articular , Swine , Animals , Cryopreservation/methods , Tissue Preservation , Magnetic Resonance Imaging
8.
JCI Insight ; 8(1)2023 01 10.
Article in English | MEDLINE | ID: mdl-36413391

ABSTRACT

Antibiotic-induced shifts in the indigenous gut microbiota influence normal skeletal maturation. Current theory implies that gut microbiota actions on bone occur through a direct gut/bone signaling axis. However, our prior work supports that a gut/liver signaling axis contributes to gut microbiota effects on bone. Our purpose was to investigate the effects of minocycline, a systemic antibiotic treatment for adolescent acne, on pubertal/postpubertal skeletal maturation. Sex-matched specific pathogen-free (SPF) and germ-free (GF) C57BL/6T mice were administered a clinically relevant minocycline dose from age 6-12 weeks. Minocycline caused dysbiotic shifts in the gut bacteriome and impaired skeletal maturation in SPF mice but did not alter the skeletal phenotype in GF mice. Minocycline administration in SPF mice disrupted the intestinal farnesoid X receptor/fibroblast growth factor 15 axis, a gut/liver endocrine axis supporting systemic bile acid homeostasis. Minocycline-treated SPF mice had increased serum conjugated bile acids that were farnesoid X receptor (FXR) antagonists, suppressed osteoblast function, decreased bone mass, and impaired bone microarchitecture and fracture resistance. Stimulating osteoblasts with the serum bile acid profile from minocycline-treated SPF mice recapitulated the suppressed osteogenic phenotype found in vivo, which was mediated through attenuated FXR signaling. This work introduces bile acids as a potentially novel mediator of gut/liver signaling actions contributing to gut microbiota effects on bone.


Subject(s)
Minocycline , Osteogenesis , Animals , Mice , Anti-Bacterial Agents/adverse effects , Bile Acids and Salts/metabolism , Liver/metabolism , Mice, Inbred C57BL , Minocycline/pharmacology
9.
iScience ; 25(9): 104818, 2022 Sep 16.
Article in English | MEDLINE | ID: mdl-36034228

ABSTRACT

Osteogenesis imperfecta (OI) is characterized by repeated bone fractures. Recent studies have shown that T lymphocytes and regulatory T cells (Tregs) regulate the functions of osteoclasts and osteoblasts, thus playing a role in bone turnover. We demonstrate an activated effector phenotype and higher secretion of pro-inflammatory cytokines, IFN-γ, and TNF-α in OI peripheral T cells as compared with wild-type (WT). Suppressive Tregs (spleen and thymus) were qualitatively similar, whereas there was a quantitative decrease in OI versus WT. Restoring Treg numbers by systemic transplantation in OI mice resulted in reduced T cell activation and effector cytokine secretion that correlated with significant improvements in tibial trabecular and cortical bone parameters and stiffness of femur, along with increased osteoblast mineralization and decreased osteoclast numbers. Therefore, Tregs can dampen the pro-inflammatory environment and enhance bone remodeling in OI mice. Thus, this study will be helpful in developing future autologous immunotherapy-based treatment modalities for OI.

10.
Stem Cells ; 39(11): 1457-1477, 2021 11.
Article in English | MEDLINE | ID: mdl-34224636

ABSTRACT

Currently, there is no cure for osteogenesis imperfecta (OI)-a debilitating pediatric skeletal dysplasia. Herein we show that hematopoietic stem cell (HSC) therapy holds promise in treating OI. Using single-cell HSC transplantation in lethally irradiated oim/oim mice, we demonstrate significant improvements in bone morphometric, mechanics, and turnover parameters. Importantly, we highlight that HSCs cause these improvements due to their unique property of differentiating into osteoblasts/osteocytes, depositing normal collagen-an attribute thus far assigned only to mesenchymal stem/stromal cells. To confirm HSC plasticity, lineage tracing was done by transplanting oim/oim with HSCs from two specific transgenic mice-VavR, in which all hematopoietic cells are GFP+ and pOBCol2.3GFP, where GFP is expressed only in osteoblasts/osteocytes. In both models, transplanted oim/oim mice demonstrated GFP+ HSC-derived osteoblasts/osteocytes in bones. These studies unequivocally establish that HSCs differentiate into osteoblasts/osteocytes, and HSC transplantation can provide a new translational approach for OI.


Subject(s)
Osteogenesis Imperfecta , Animals , Disease Models, Animal , Hematopoietic Stem Cells , Humans , Mice , Mice, Transgenic , Osteoblasts , Osteogenesis , Osteogenesis Imperfecta/therapy
11.
J Bone Joint Surg Am ; 102(19): 1694-1702, 2020 Oct 07.
Article in English | MEDLINE | ID: mdl-33027123

ABSTRACT

BACKGROUND: We sought to define "at risk" loading conditions associated with rotating-platform total knee arthroplasty (TKA-RP) implants that predispose to insert subluxation and spinout and to quantify tolerances for flexion-extension gap asymmetry and laxity in order to prevent these adverse events. METHODS: Biomechanical testing was performed on 6 fresh-frozen cadaveric limbs with a TKA-RP implant with use of a gap-balancing technique, followed by sequential femoral component revision with variable-thickness polyethylene inserts to systematically represent 5 flexion-extension mismatch and asymmetry conditions. Each configuration was subjected to mechanical loading at 0°, 30°, and 60°. Rotational displacement of the insert on the tibial baseplate, lateral compartment separation, and insert concavity depth were measured with use of a digital caliper. Yield torque, a surrogate for ease of insert rotation and escape of the femoral component, was calculated with use of custom MATLAB code. RESULTS: Design-intended insert rotation decreased with increasing knee flexion angles in each loading configuration. Likewise, yield torque increased with increasing joint flexion and decreased with increasing joint laxity in all testing configurations. Insert instability and femoral condyle displacement were reproduced in positions of increasing knee flexion and asymmetrical flexion gap laxity. The depth of lateral polyethylene insert concavity determined femoral condylar capture and defined a narrow tolerance of <2 mm in the smallest implant sizes for flexion gap asymmetry leading to rotational insert instability. CONCLUSIONS: Decreased femoral-tibial articular surface conformity with increasing knee flexion and asymmetrical flexion gap laxity enable paradoxical motion of the femoral component on the upper insert surface rather than the undersurface, as designed. CLINICAL RELEVANCE: Mobile-bearing TKA-RP is a technically demanding procedure requiring a snug symmetrical flexion gap. As little as 2 mm of asymmetrical lateral flexion laxity can result in decreased conformity, condyle liftoff, and insert subluxation. Flexion beyond 30° decreases bearing surface contact area and predisposes to reduced insert rotation and mechanical malfunction.


Subject(s)
Arthroplasty, Replacement, Knee/methods , Range of Motion, Articular/physiology , Biomechanical Phenomena , Cadaver , Femur/surgery , Humans , Knee Prosthesis , Male , Middle Aged , Polyethylene , Prosthesis Design , Reoperation , Rotation , Tibia/surgery , Torque
12.
Spine Deform ; 7(2): 213-219, 2019 03.
Article in English | MEDLINE | ID: mdl-30660214

ABSTRACT

STUDY DESIGN: Large animal study. OBJECTIVE: Create a thoracic hyperkyphotic deformity in an immature porcine spine, so that future researchers may use this model to validate spinal instrumentation and other therapies used in the treatment of hyperkyphosis. SUMMARY OF BACKGROUND DATA: Although several scoliotic animal models have been developed, there have been no reports of a thoracic hyperkyphotic animal model creation in an immature animal. The present study was designed to produce a porcine hyperkyphotic model by the time the pig weighed 25 kg, which corresponds to the approximate weight of a child undergoing surgery for early-onset scoliosis (EOS). METHODS: Successful surgical procedures were performed in 6 consecutive 10-kg (male, 5-week-old) immature Yorkshire pigs. Procedure protocol consisted of 1) a left thoracotomy at T10-T11, 2) screw placement at T9 and T11, 3) partial vertebrectomy at T10, 4) posterior interspinous ligament transection, and 5) placement of wire loop around screws and tightening. Weekly x-ray imaging was performed preoperatively and postoperatively, documenting progressively increasing kyphosis as the pig grew. Necropsy was performed 5-6 weeks after surgery, with CT, slab section, and histologic analysis. RESULTS: Average T9-T11 kyphosis (measured by sagittal Cobb angle) was 6.1° ± 1.4° (mean ± SD) preoperatively, 30.5° ± 1.0° immediately postoperation, and significantly increased to 50.3° ± 7.2° (p < .0001) over 5-6 weeks in 6 consecutive pigs at time of necropsy. CONCLUSIONS: An animal model of relatively more rigid-appearing thoracic hyperkyphotic deformities in immature pigs has been created. Subsequent studies addressing management of early-onset kyphosis with spinal instrumentation are now possible. LEVEL OF EVIDENCE: Level V.


Subject(s)
Disease Models, Animal , Kyphosis , Swine , Animals , Male , Thoracic Vertebrae
13.
Clin Orthop Relat Res ; 476(10): 2076-2090, 2018 10.
Article in English | MEDLINE | ID: mdl-30024459

ABSTRACT

BACKGROUND: External beam irradiation is an accepted treatment for skeletal malignancies. Radiation acts on both cancerous and normal cells and, depending on the balance of these effects, may promote or impair bone healing after pathologic fracture. Previous studies suggest an adverse effect of radiation on endochondral ossification, but the existence of differential effects of radiation on the two distinct bone healing pathways is unknown. QUESTIONS/PURPOSES: The purpose of this study was to investigate the differential effects of external beam irradiation on endochondral compared with intramembranous ossification with intramedullary nail and plate fixation of fractures inducing the two respective osseous healing pathways through assessment of (1) bone biology by histomorphometric analysis of cartilage area and micro-CT volumetric assessment of the calcified callus; and (2) mechanical properties of the healing fracture by four-point bending failure analysis of bending stiffness and strength. METHODS: Thirty-six male Sprague-Dawley rats underwent bilateral iatrogenic femur fracture: one side was repaired with an intramedullary nail and the other with compression plating. Three days postoperatively, half (n = 18) received 8-Gray external beam irradiation to each fracture. Rodents were euthanized at 1, 2, and 4 weeks postoperatively (n = 3/group) for quantitative histomorphometry of cartilage area and micro-CT assessment of callus volume. The remaining rodents were euthanized at 3 months (n = 9/group) and subjected to four-point bending tests to assess stiffness and maximum strength. RESULTS: Nailed femurs that were irradiated exhibited a reduction in cartilage area at both 2 weeks (1.08 ± 1.13 mm versus 37.32 ± 19.88 mm; 95% confidence interval [CI] of the difference, 4.32-68.16 mm; p = 0.034) and 4 weeks (4.60 ± 3.97 mm versus 39.10 ± 16.28 mm; 95% CI of the difference, 7.64-61.36 mm; p = 0.023) compared with nonirradiated fractures. There was also a decrease in the volume ratio of calcified callus at 4 weeks (0.35 ± 0.08 versus 0.51 ± 0.05; 95% CI of the difference, 0.01-0.31; p = 0.042) compared with nonirradiated fractures. By contrast, there was no difference in cartilage area or calcified callus between irradiated and nonirradiated plated femurs. The stiffness (128.84 ± 76.60 N/mm versus 26.99 ± 26.07 N/mm; 95% CI of the difference, 44.67-159.03 N/mm; p = 0.012) and maximum strength (41.44 ± 22.06 N versus 23.75 ± 11.00 N; 95% CI of the difference, 0.27-35.11 N; p = 0.047) of irradiated plated femurs was greater than the irradiated nailed femurs. However, for nonirradiated femurs, the maximum strength of nailed fractures (36.05 ± 17.34 N versus 15.63 ± 5.19 N; 95% CI of the difference, 3.96-36.88 N; p = 0.022) was greater than plated fractures, and there was no difference in stiffness between the nailed and plated fractures. CONCLUSIONS: In this model, external beam irradiation was found to preferentially inhibit endochondral over intramembranous ossification with the greatest impairment in healing of radiated fractures repaired with intramedullary nails compared with those fixed with plates. Future work with larger sample sizes might focus on further elucidating the observed differences in mechanical properties. CLINICAL RELEVANCE: This work suggests that there may be a rationale for compression plating rather than intramedullary nailing of long bone fractures in select circumstances where bony union is desirable, adjunctive radiation treatment is required, and bone stock is sufficient for plate and screw fixation.


Subject(s)
Femoral Fractures/therapy , Femur/radiation effects , Femur/surgery , Fracture Healing/radiation effects , Osteogenesis/radiation effects , Radiation Dosage , Animals , Bone Nails , Bone Plates , Combined Modality Therapy , Disease Models, Animal , Femoral Fractures/diagnostic imaging , Femoral Fractures/physiopathology , Femur/diagnostic imaging , Femur/physiopathology , Fracture Fixation, Intramedullary/instrumentation , Male , Rats, Sprague-Dawley , Time Factors , X-Ray Microtomography
14.
JAMA Otolaryngol Head Neck Surg ; 144(9): 769-775, 2018 09 01.
Article in English | MEDLINE | ID: mdl-30054621

ABSTRACT

Importance: The chimeric anterolateral thigh osteomyocutaneous (ALTO) free flap is a recently described microvascular option for head and neck osseous defects associated with complex soft-tissue requirements. To date, the association of ALTO flap harvest with femur structural integrity and the need for routine prophylactic fixation following harvest has been incompletely described. Objective: To investigate the association of ALTO flap harvest, with and without prophylactic fixation, on femur structural integrity as measured by 4-point bend and torsional biomechanical testing. Design and Setting: At a research laboratory, 24 synthetic fourth-generation composite femurs with validated biomechanical properties underwent 10-cm-long, 30% circumferential osteotomies at the proximal middle third of the femur; 6 femurs served as controls. Osteotomized femurs with and without fixation underwent torsional and 4-point bend biomechanical testing. Femur fixation consisted of intramedullary nail and distal interlock screw placement. Main Outcomes and Measures: Force and torque to fracture (expressed in kilonewtons [kN] and Newton meters [N∙m], respectively) were compared between controls, osteotomized femurs without fixation, and osteotomized femurs with fixation. Additional outcome measures included femur stiffness and fracture patterns. Results: On posterior to anterior (PA) 4-point bend testing, force to fracture of osteotomized femurs was 22% of controls (mean difference, 8.3 kN; 95% CI, 6.6-10.0 kN). On torsional testing the torque to fracture of osteotomized femurs was 12% of controls (mean difference, 351.1 N∙m; 95% CI, 307.1-395.1 N∙m). Following fixation there was a 67% improvement in PA force to fracture and a 37% improvement in torque to fracture. However, osteotomized femurs with fixation continued to have a reduced PA force to fracture at 37% of controls (mean difference, 6.8 kN; 95% CI, 4.5-9.2 kN) and torque to fracture at 16% of controls (mean difference, 333.7 N∙m; 95% CI, 306.8-360.6 N∙m). On torsional testing, all osteotomized femurs developed similar spiral fractures through a corner of the distal osteotomy site. This fracture pattern changed after prophylactic fixation with femurs developing nondisplaced fractures through the proximal osteotomy site. There were no underlying hardware failures during testing of osteotomized femurs with fixation. Conclusions and Relevance: Anterolateral thigh osteomyocutaneous flap harvest results in significant changes in the structural integrity of the femur. Postoperative stabilization should be strongly considered, with future research directed at investigating the clinical significance of residual biomechanical changes following femur fixation.


Subject(s)
Bone Transplantation/methods , Femur/surgery , Fracture Fixation, Intramedullary/methods , Free Tissue Flaps/transplantation , Myocutaneous Flap/transplantation , Osteotomy , Plastic Surgery Procedures/methods , Adult , Aged , Biomechanical Phenomena , Bone Nails , Bone Screws , Femoral Fractures/etiology , Femoral Fractures/prevention & control , Femur/pathology , Fracture Fixation, Intramedullary/instrumentation , Humans , Male , Middle Aged , Models, Anatomic , Osteotomy/adverse effects , Osteotomy/methods , Postoperative Complications/prevention & control , Thigh
15.
ACS Appl Mater Interfaces ; 10(24): 20237-20243, 2018 Jun 20.
Article in English | MEDLINE | ID: mdl-29873237

ABSTRACT

Memristors with rich interior dynamics of ion migration are promising for mimicking various biological synaptic functions in neuromorphic hardware systems. A graphene-based memristor shows an extremely low energy consumption of less than a femtojoule per spike, by taking advantage of weak surface van der Waals interaction of graphene. The device also shows an intriguing programmable metaplasticity property in which the synaptic plasticity depends on the history of the stimuli and yet allows rapid reconfiguration via an immediate stimulus. This graphene-based memristor could be a promising building block toward designing highly versatile and extremely energy efficient neuromorphic computing systems.

16.
Ann Biomed Eng ; 46(2): 310-317, 2018 Feb.
Article in English | MEDLINE | ID: mdl-29181723

ABSTRACT

To investigate potential mechanisms associated with the increased prevalence of temporomandibular joint (TMJ) disorders among women, the study objective was to determine sex-dependent and region-dependent differences in fixed charge density (FCD) using an electrical conductivity method. Seventeen TMJ discs were harvested from nine males (77 ± 4 years) and eight females (86 ± 4 years). Specimens were prepared from the anterior band, posterior band, intermediate zone, medial disc and lateral disc. FCD was determined using an electrical conductivity method, assessing differences among disc regions and between sexes. Statistical modeling showed significant effects for donor sex (p = 0.002), with cross-region FCD for male discs 0.051 ± 0.018 milliequivalent moles per gram (mEq/g) wet tissue and 0.043 ± 0.020 mEq/g wet tissue for female discs. FCD was significantly higher for male discs compared to female discs in the posterior band, with FCD 0.063 ± 0.015 mEq/g wet tissue for male discs and 0.032 ± 0.020 mEq/g wet tissue for female discs (p = 0.050). These results indicate FCD contributes approximately 20% towards TMJ disc compressive modulus, through osmotic swelling pressure regulation. Additionally, FCD regulates critical extracellular ionic/osmotic and nutrient environments. Sexual dimorphisms in TMJ disc FCD, and resulting differences in extracellular ionic/osmotic and nutrient environments, could result in altered mechano-electro-chemical environments between males and females and requires further study.


Subject(s)
Electric Conductivity , Sex Characteristics , Temporomandibular Joint Disc/physiology , Aged , Aged, 80 and over , Female , Humans , Male , Temporomandibular Joint Disc/anatomy & histology
17.
Spine (Phila Pa 1976) ; 43(2): E60-E67, 2018 Jan 15.
Article in English | MEDLINE | ID: mdl-28542098

ABSTRACT

STUDY DESIGN: In vitro measurements of the oxygen consumption rates (OCR) of human intervertebral disc (IVD) cells. OBJECTIVE: The aim of this study was to determine the differences in the OCR of nondegenerate and degenerate human annulus fibrosus (AF), nucleus pulposus (NP), and cartilage endplate (CEP) cells at different glucose concentrations. SUMMARY OF BACKGROUND DATA: The avascular nature of the IVD creates a delicate balance between rate of nutrient transport through the matrix and rate of disc cell consumption necessary to maintain tissue health. Previous studies have shown a dependence of OCR for animal (e.g., bovine and porcine) IVD cells on oxygen level and glucose concentration. However, the OCR of nondegenerate human IVD cells compared to degenerate human IVD cells at different glucose concentrations has not been investigated. METHODS: IVD cells were isolated from the AF, NP, and CEP regions of human cadaver spines and surgical samples. The changes in oxygen concentration were recorded when cells were sealed in a metabolic chamber. The OCR of cells was determined by curve fitting using the Michaelis-Menton equation. RESULTS: Under identical cell culture conditions, the OCR of degenerate human IVD cells was three to five times greater than that of nondegenerate human IVD cells. The degenerate IVD cells cultured in low-glucose medium (1 mmol/L) exhibited the highest OCR compared to degenerate cells cultured at higher glucose levels (i.e., 5 mmol/L, 25 mmol/L), whereas no significant differences in OCR were found among the nondegenerate IVD cells for all glucose levels. CONCLUSION: Considering the significantly higher OCR and unique response to glucose of degenerate human IVD cells, the degeneration of the IVD is associated with a cell phenotypic change related to OCR. The OCR of IVD cells reported in this study will be valuable for understanding human IVD cellular behavior and tissue nutrition in response to disc degeneration. LEVEL OF EVIDENCE: N/A.


Subject(s)
Annulus Fibrosus/physiopathology , Cartilage/physiopathology , Intervertebral Disc Degeneration/physiopathology , Nucleus Pulposus/physiopathology , Oxygen Consumption , Adult , Aged , Annulus Fibrosus/cytology , Cartilage/cytology , Female , Glucose/pharmacology , Humans , Male , Middle Aged , Nucleus Pulposus/cytology , Oxygen Consumption/drug effects , Young Adult
18.
Spine (Phila Pa 1976) ; 42(17): E1002-E1009, 2017 Sep 01.
Article in English | MEDLINE | ID: mdl-28699925

ABSTRACT

STUDY DESIGN: Regional measurements of fixed charge densities (FCDs) of healthy human cartilage endplate (CEP) using a two-point electrical conductivity approach. OBJECTIVE: The aim of this study was to determine the FCDs at four different regions (central, lateral, anterior, and posterior) of human CEP, and correlate the FCDs with tissue biochemical composition. SUMMARY OF BACKGROUND DATA: The CEP, a thin layer of hyaline cartilage on the cranial and caudal surfaces of the intervertebral disc, plays an irreplaceable role in maintaining the unique physiological mechano-electrochemical environment inside the disc. FCD, arising from the carboxyl and sulfate groups of the glycosaminoglycans (GAG) in the extracellular matrix of the disc, is a key regulator of the disc ionic and osmotic environment through physicochemical and electrokinetic effects. Although FCDs in the annulus fibrosus (AF) and nucleus pulposus (NP) have been reported, quantitative baseline FCD in healthy human CEP has not been reported. METHODS: CEP specimens were regionally isolated from human lumbar spines. FCD and ion diffusivity were concurrently investigated using a two-point electrical conductivity method. Biochemical assays were used to quantify regional GAG and water content. RESULTS: FCD in healthy human CEP was region-dependent, with FCD lowest in the lateral region (P = 0.044). Cross-region FCD was 30% to 60% smaller than FCD in NP, but similar to the AF and articular cartilage (AC). CEP FCD (average: 0.12 ±â€Š0.03 mEq/g wet tissue) was correlated with GAG content (average: 31.24 ±â€Š5.06 µg/mg wet tissue) (P = 0.005). In addition, the cross-region ion diffusivity in healthy CEP (2.97 ±â€Š1.00 × 10 cm/s) was much smaller than the AF and NP. CONCLUSION: Healthy human CEP acts as a biomechanical interface, distributing loads between the bony vertebral body and soft disc tissues and as a gateway impeding rapid solute diffusion through the disc. LEVEL OF EVIDENCE: N/A.


Subject(s)
Electric Conductivity , Hyaline Cartilage , Intervertebral Disc , Electrophysiological Phenomena , Humans , Hyaline Cartilage/chemistry , Hyaline Cartilage/physiology , Intervertebral Disc/chemistry , Intervertebral Disc/physiology
19.
J Biomech ; 49(13): 2756-2762, 2016 09 06.
Article in English | MEDLINE | ID: mdl-27338525

ABSTRACT

The cartilage endplate (CEP) is implicated as the main pathway of nutrient supply to the healthy human intervertebral disc (IVD). In this study, the diffusivities of nutrient/metabolite solutes in healthy CEP were assessed, and further correlated with tissue biochemical composition and structure. The CEPs from non-degenerated human IVD were divided into four regions: central, lateral, anterior, and posterior. The diffusivities of glucose and lactate were measured with a custom diffusion cell apparatus under 0%, 10%, and 20% compressive strains. Biochemical assays were conducted to quantify the water and glycosaminoglycan (GAG) contents. The Safranin-O and Ehrlich׳s hematoxylin and eosin staining and scanning electron microscopy (SEM) were performed to reveal the tissue structure of the CEP. Average diffusivities of glucose and lactate in healthy CEP were 2.68±0.93×10-7cm2/s and 4.52±1.47×10-7cm2/s, respectively. Solute diffusivities were region-dependent (p<0.0001) with the highest values in the central region, and mechanical strains impeded solute diffusion in the CEP (p<0.0001). The solute diffusivities were significantly correlated with the tissue porosities (glucose: p<0.0001, r=0.581; lactate: p<0.0001, r=0.534). Histological and SEM studies further revealed that the collagen fibers in healthy CEP are more compacted than those in the nucleus pulposus (NP) and annulus fibrosus (AF) and show no clear orientation. Compared to human AF and NP, much smaller solute diffusivities in human CEP suggested that it acts as a gateway for solute diffusion through the disc, maintaining the balance of nutritional environment in healthy human disc under mechanical loading and preventing the progression of disc degeneration.


Subject(s)
Cartilage/metabolism , Glucose/metabolism , Intervertebral Disc/metabolism , Lactic Acid/metabolism , Stress, Mechanical , Diffusion , Female , Glycosaminoglycans/metabolism , Humans , Intervertebral Disc/physiology , Intervertebral Disc Degeneration/metabolism , Male , Middle Aged , Water/metabolism
20.
J Biomech ; 48(12): 3185-91, 2015 Sep 18.
Article in English | MEDLINE | ID: mdl-26209084

ABSTRACT

Regional biomechanical and biochemical properties of bovine cartilaginous endplate (CEP) and its role in disc mechanics and nutrition were determined. The equilibrium aggregate modulus and hydraulic permeability between the central and lateral regions were examined by confined compression testing. Biochemical assays were conducted to quantify the amount of water, collagen, and glycosaminoglycan (GAG). The equilibrium aggregate modulus of the CEP in the central region (0.23 ± 0.15 MPa) was significantly lower than for the lateral region (0.83 ± 0. 26 MPa). No significant regional difference was found for the permeability of the CEP (central region: 0.13 ± 0.07×10(-15)m(4)/Ns and lateral region: 0.09 ± 0.03 × 10(-15)m(4)/Ns). CEPs were an average of 75.6% water by wet weight, 41.1% collagen, and 20.4% GAG by dry weight in the central region, as well as an average of 70.2% water by wet weight, 73.8% collagen, and 11.7% GAG by dry weight in the lateral region. Regional differences observed for the equilibrium aggregate modulus were likely due to the regional variation in biochemical composition. The lateral bovine endplate is much stiffer and may share a greater portion of the load. Compared with the nucleus pulposus (NP) and annulus fibrosus (AF), a smaller hydraulic permeability was found for the CEP in both the central and lateral regions, which could be due to its lower water content and higher collagen content. Our results suggest that the CEP may block rapid fluid exchange and solute convection, allow pressurization of the interstitial fluid, and play a significant role in nutrient supply in response to loading.


Subject(s)
Intervertebral Disc/physiology , Animals , Biomechanical Phenomena , Cattle , Collagen/chemistry , Elastic Modulus , Glycosaminoglycans/chemistry , Intervertebral Disc/anatomy & histology , Male , Permeability , Viscosity , Water/chemistry
SELECTION OF CITATIONS
SEARCH DETAIL
...